============================= Response of a designed filter ============================= .. image:: ../API/img/colorCode.svg A filter block of a system diagram runs a filter design: a Laplace transfer with a method, made by ``sl.createIIR()`` or ``sl.createFIR()`` in a design script in ``lib/``. Its frequency response and its impulse and step responses show what the run computes, next to the response of the Laplace transfer. This page describes how to plot them. Make the filter =============== An instruction file makes the filter from its design script: .. code-block:: python FLT1 = sl.makeFilter("lib/filter_a.py", Ts="10u", params=sl.selectPars("system1", circuit=["f_c"])) ``makeFilter()`` runs the design script, as a system run does. The filter is therefore never out of date. Do not define the design a second time in the instruction file. The design script is the design the diagram runs, and a copy would not follow a change of it. ``makeFilter()`` fixes the sample period and the parameter values of the response, as a SLiCAP instruction fixes its result. The traces of the filter are then made for these values. On a system diagram, :menuselection:`Instruction --> Make filter…` writes this line. Its dialog lists the design scripts of the project. Sample period ============= - A *stationary* filter has a sample period of its own. It always uses it. A Ts given to ``makeFilter()`` is not used. The dialog shows the filter's own Ts, greyed out. - A stationary filter can take its sample period from a parameter pin. The pin is then a parameter like the others, with its value in ``params``. - A *non-stationary* filter follows the clock it runs on, and has no sample period of its own. Give the clock period as Ts: a number, or the name of a parameter in ``params``. Parameter values ================ A design with parameters needs a value for each of them. The Make filter dialog takes them from the parameter table of the instruction dialogs. For each parameter you choose its source: - **system**: the sheet parameter of a system diagram that runs the design. The dialog offers the diagrams whose run script lists the design script. - **specs**: the specification item with the same name. - **user**: a value typed in the table. The values are read when the line runs. The dialog writes them as ``params=sl.selectPars("", ...)``. Without a diagram the first argument is ``None``. A value may be an expression in other parameters of ``params``. Errors ====== ``makeFilter()`` makes something that later lines use. When it cannot be made, it raises an error, and the script stops at the cause: - the design script does not exist; - the design script makes no filter, or more than one; - a parameter has no numeric value; - a non-stationary filter has no positive Ts. The dialog prevents these errors: :guilabel:`Add instruction` stays disabled until everything is given. Traces ====== In :menuselection:`Instruction --> Create / Edit Traces and Measurements…` choose the filter as the analysis result. Choose the domain and the range. The dialog fills in the standard traces: in the frequency domain ``dB(mag(H_z))`` and ``dB(mag(H_s))``, in the time domain ``step``. Edit or remove them as needed. The dialog writes the line, for instance: .. code-block:: python TR1 = sl.make_traces(sl.sweepData(FLT1, "10", "50k", 200), [{"y": "dB(mag(H_z))"}, {"y": "dB(mag(H_s))"}]) ``sl.sweepData()`` only makes the x-y data for the range. The sample period and the parameter values are those of ``makeFilter()``. The signals of a filter: - **Frequency domain:** - ``H_z``: the response of the filter as the run computes it, with z = exp(j2πf·Ts); - ``H_s``: the response of its Laplace transfer, with s = j2πf. Both are complex. ``mag(H_z)`` is the magnitude and ``dB(mag(H_z))`` the magnitude in dB. ``phase(H_z)`` is the phase in degrees and ``delay(H_z)`` the group delay. The same holds for ``H_s``. - **Time domain**, ``sweepVar="t"``, at the sample times k·Ts: - ``impulse``: the response to one sample of value 1, divided by Ts. It then lies on the impulse response of the Laplace transfer (``doImpulse()``). - ``step``: the step response. The number of points is not used: the samples lie at k·Ts. They are drawn as points. A trace specification with a style, such as ``{"y": "step", "lineType": "-"}``, overrides that. To compare two sets of values, make the filter twice, as ``FLT1`` and ``FLT2``, and plot both. What the run computes ===================== The traces are computed as the run computes the filter: - A stationary IIR filter runs as a cascade of second-order and first-order sections. - A non-stationary IIR filter runs as the state-space form of its whole transfer, stepped exactly over each tick: zoh for a held input, foh for an input linear between the samples. For a held step the step response at the sample times then equals the step response of the Laplace transfer. - A FIR filter runs as its taps. The transfers of the filter =========================== ``makeFilter()`` gives the filter two transfers, with every parameter value substituted: - ``FLT1.H_s``: the Laplace transfer, an expression in ``s``; - ``FLT1.H_z``: the z-transfer that the run executes, an expression in ``z``, for the sample period ``FLT1.Ts``. ``sl.sweepData()`` evaluates them. They can also be combined, like the ``laplace`` attribute of a SLiCAP result. ``sl.sweepData()`` sweeps an expression in ``s`` and gives it the signal ``H_s``. For instance, the admittances of two models of one component, added: .. code-block:: python Y = FLT1.H_s + FLT2.H_s D3 = sl.sweepData(Y, "1k", "100M", 500) TR3 = sl.make_traces(D3, [{"y": "dB(mag(H_s))"}]) An expression in ``z`` needs its sample period. ``sl.z2fourier()`` turns it into a frequency response: .. code-block:: python Hf = sl.z2fourier(FLT1.H_z, FLT1.Ts) The z-transfer is a product of first-order and second-order factors, not one numerator and one denominator polynomial. With many poles close to z = 1, a filter at a low frequency compared with the sample rate, the coefficients of one polynomial lose their accuracy in floating point. The factors of a non-stationary filter are computed with 50 digits. ``sl.sweepData()`` evaluates the factors one by one. The attributes of the filter ============================ Set by ``createIIR()`` or ``createFIR()`` in the design script: - ``name``, ``dataType`` ("iir" or "fir"), ``method``, and for a FIR filter ``window`` and ``length``; - ``laplace``: the Laplace transfer, with the parameters as symbols; - ``params``: the names of the parameters; - ``stationary``; - ``Ts``: the filter's own sample period, None for a non-stationary filter; - ``ts_param``: the name of the parameter that gives Ts, or None. Set by ``makeFilter()``: - ``Ts``: for a non-stationary filter the clock period, for a Ts parameter its value; - ``values``: the parameter values; - ``H_s`` and ``H_z``: the transfers above. The pins of a filter block and the link to the circuit of its design belong to the block, not to the filter. The editor reads the circuit from the ``makeCircuit()`` line of the design script.